Kinetic Phosphorescence Analyzers for trace level detection of Uranium & Lanthanides

The KPA-11 is a fast, accurate and economical method for precise detection of trace levels of uranium and lanthanides in a wide variety of biological and environmental samples.

KPA models to choose from:


KPAWin Software

KPA - Kinetic Phosphorescence Analyzers for trace level detection of Uranium & Lanthanides

Chemchek's KPAWin software controls the operation of the KPA-11 along with the storage and manipulation of analytical data. Click here for more information.

 

 



KPA-11 Manual

Uranium and Lanthanides laser induced mining trace amounts of uranium time resolved detection analyzer`The KPA-11 Manual is the basic instrument for uranium analysis. The KPA-11M performs single-measurement, quench-corrected highly specific analyses of the 1-2 ml sample placed in the quartz cuvette. The KPA-11M offers extensive time resolution and luminescence lifetime capabilities for additional specificity. Interferences are avoided while obtaining precise and sensitive measurements down to 0.01 µg/L.

 


  • Low detection limits
  • Ease of sample prep
  • Lower analytical costs
  • Precise and reproducible results

KPA - Kinetic Phosphorescence Analyzers for trace level detection of Uranium & LanthanidesKPA-11 Specifications



KPA-11 With Automatic Sample Changer

The KPA-11 Automatic includes the Gilson Model 223 Sample changer (which allows continuous operation for 42 to 108 samples depending on rack configuration), the Gilson Model 402 Dilutor, KPA application software, tubing kit, and one flow-through cell.
KPA - Kinetic Phosphorescence Analyzers for trace level detection of Uranium & Lanthanides`

The KPA-11 Automatic can analyze up to 108 samples. The system automatically mixes the sample with enhancing reagent before each measurement and injects the sample in scintillation vials using an automatic sample changer. Cell flushing and decontamination are fully automatic. Fast measurements of hundreds of samples a day can be accomplished with reduced time demand on the operator.
  • Automatic mix of sample and enhancing reagent
  • Automatic cell flushing and decontamination
  • Reduced operator time
  • Greater accuracy in analysis
  • Reduced contamination of sample cells

Uranium and Lanthanides laser induced mining trace amounts of uranium time resolved detection analyzer`KPA-11 Specifications



KPA-11 with Tunable Dye Module

KPA - Kinetic Phosphorescence Analyzers for trace level detection of Uranium & Lanthanides
The basic KPA with tunable dye module allows for selection of a specific wavelength for excitation. This method is recommended when the KPA will be used to detect more than one element. The KPA can be used to determine U, Tb, Eu, Sm, Dy, and Tm.

KPA - Kinetic Phosphorescence Analyzers for trace level detection of Uranium & LanthanidesKPA-11 Specifications



KPA-11 with Remote Sample Chamber

KPA - Kinetic Phosphorescence Analyzers for trace level detection of Uranium & Lanthanides

The KPA with the remote sample compartment assembly is used for analyzing samples in hostile environments. The remote sample chamber is compact and is designed to be used in a glove box with the main KPA stationed outside. The chamber is connected to the KPA through a fiber optic cable. It can be placed up to 3 meters from the KPA electronics.pan>

Uranium and Lanthanides laser induced mining trace amounts of uranium time resolved detection analyzerKPA-11 Specifications